Endurity

Dual-chamber Pacemaker

Product Highlights — Pacemaker

Allows patients to undergo MRI scans when used with MRI Ready leads from Abbott.*

Physician-preferred size and physiologic shape minimize pocket size. Outstanding longevity provides 9,7 years of service life,1 which is supported by an eight-year warranty.2

AutoCapture™ pacing system offers the maximum in threshold adaptability and patient safety with ventricular Beat-by-Beat™ AutoCapture™ pacing systems capture confirmation. The AutoCapture pacing system automatically delivers a 5,0 V backup safety pulse when noncapture is detected, and it may be programmed to either a bipolar or unipolar configuration.

A suite of state-of-the-art features — complete automaticity (atrial and ventricular), Ventricular Intrinsic Preference (VIP™) technology, the AF Suppression™ algorithm and SenseAbility™ sensing algorithm technology — is designed to deliver optimal therapy for patients at implant and throughout their lives.

The only pacemaker with programmable AT/AF alerts specifically indicated for detecting atrial tachyarrhythmias, which have been found to be associated with an increased risk of stroke in elderly, hypertensive, pacemaker patients without prior history of AF.3

  • Real-time electrogram (EGM) waveform, as well as the associated event markers that precede and follow a specific triggering event, can be programmed to automatically record up to 14 minutes of stored EGMs when encountering one or more programmable trigger options.
  • An optional, easy-to-use handheld device (SJM MRI Activator™ device) can be used to program the device to preapproved MRI settings pre- and post MRI scan, decreasing the number of workflow steps and increasing clinic efficiency.
  • Six-month ERI-EOL interval

Assurity

Single-Chamber Pacemaker

Product Highlights — Pacemaker

  • Allows patients to undergo MRI scans when used with an MRI Ready lead from Abbott.*
  • Physician-preferred size and physiologic shape minimize pocket size.
  • Outstanding longevity provides 14,4 years of service life,1 which is supported by a 10-year warranty.2
  • AutoCapture™ pacing system offers the maximum in threshold adaptability and patient safety with ventricular Beat-by-Beat™ AutoCapture™ pacing systems capture confirmation. The AutoCapture pacing system automatically delivers a 5,0 V backup safety pulse when noncapture is detected, and it may be programmed to either a bipolar or unipolar configuration.
  • A suite of state-of-the-art features — such as automaticity, ventricular AutoCapture™ pacing system and SenseAbility™ sensing algorithm technology — are designed to deliver optimal therapy for patients at implant and throughout their lives.

Real-time electrogram (EGM) waveform, as well as the associated event markers that precede and follow a specific triggering event, can be programmed to automatically record up to 14 minutes of stored EGMs when encountering one or more programmable trigger options.

  • An optional, easy-to-use handheld device (SJM MRI Activator™ device) can be used to program the device to preapproved MRI settings pre- and post MRI scan, decreasing the number of workflow steps and increasing clinic efficiency.
  • Six-month ERI-EOL interval.

Quadra Allure

Cardiac Resynchronization Therapy
Pacemaker

Product Highlights

  • Allows patients to undergo MRI scans when used with MRI Ready leads from Abbott.
  • The Quadra Allure™ CRT-P and Quartet™ quadripolar LV pacing lead feature four pacing electrodes and 14 pacing vectors to provide more options and greater control to address complications at and post implant to improve CRT response.
  • SyncAV™ CRT technology dynamically adjusts AV delays based on patient’s intrinsic conduction to encourage patient-tailored biventricular pacing.
  • Elevate Response Easily with Auto VectSelect Quartet™ Test offering an efficient workflow for complete results and programming at the touch of a button.
  • Angled header and physiologic tear drop shape providebetter lead wrap.
  • CorVue™ Congestion Monitoring feature monitors the intrathoracic impedance and provides the option for both patient and physician alerts.
  • The DirectTrend™ Report provides a summary of three month daily, one year weekly or one year daily diagnostic trends.

Better patient utilization from day one when paired with the Merlin@home™ transmitter at point of care1

  • AT/AF alerts can be programmed to notify their clinics when a programmed AT/AF threshold or continuous episode duration has been exceeded, or when a high ventricular rate accompanies the AT/AF episode.
  • Exclusive AF Suppression™ algorithm is clinically proven to suppress episodes of paroxysmal and persistent AF
  • AT/AF burden trend provides a graphical representation of the percentage of time in AT/AF and the number of AT/AF episodes in the previous 52 weeks
  • Up to 14 minutes of stored electrograms help identify key intrinsic and pacemaker-related events and simplify the diagnosis of complex ECG rhythms associated with heart failure.
  • Longevity offers 8,2 years of service life supported by a six year warranty.